The BridgeWay J1939 to Modbus
Interface
(p/n AB7606) provides connectivity between a Modbus RTU (serial) network and a J1939 Heavy Duty vehicle (CAN) network. The JMI appears as a Modbus Slave device to a Modbus Master device, allowing the Modbus Master to read or write data from/to the J1939 network. Pyramid Solutions provides the JMI with a Windows-based configuration tool (BWConfig). This PC-based software allows the user to map J1939 parameter (PGN) data into a range of memory addressable through the JMI Modbus RTU interface.
Configuration of the JMI is simple using BWConfig and consists of setting up an I/O table containing selected J1939 PGNs and the rate that each will be read or written from the J1939 network. BWConfig will then automatically map the I/O table to a range of addresses accessible from the JMI Modbus RTU interface. The configuration is downloaded from the PC to the JMI via an RS232 connection and is saved in FLASH memory.
Print Data Sheet | Request Pricing
Click here to access AB7606 files & information!
Example Use Cases
- Low-cost interface used on
Oil & Gas equipment to access engine parameters from a Programmable Logic Controller (PLC)
- An on-vehicle gateway used to interface a J1939 network to an onboard industrial automation based control system